OWNER:
Hattiesburg Hotels, Inc.
P.O. Box 1994
Laurel, MS 39441
PROJECT
ARCHITECT:
W. Charles Holland
112 Dixon Lane
Pensacola, FL 32507
SEGMENTAL
WALL DESIGN/BUILD COMPANY:
Synergy Earth Systems, LLC.
26240 Equity Drive
Daphne, AL 36526
Located at the
intersection of I-59 and US 49 and near the campus of the University
of Southern Mississippi, the site location for the Sleep Inn development
is ideal. Unfortunately, the site topography was less than ideal.
In order to create enough room for the structure and the parking
areas, several retaining walls were needed. In some areas, the parking
came up to the back of the walls. In other areas, the building came
as close as 10' to the back edge of the wall. To further complicate
matters, the soils on site were not suitable for use as backfill
behind the walls. Faced with several critical design issues, the
owner called Synergy to provide a design/build pagckage for the
walls on his site. .
Synergy worked
closely with the owner's design team to make sure that all of the
design issues were addressed for this site. The design had to consider
items such as global stability and the loadings from the building
foundations. With in-house engineers preparing plans, Synergy addressed
the critical needs of the project. The final design consisted of
5 retaining walls that amounted to almost 12,000 sf. The project
was completed in September 2007.